The PARK1® 

Combines a non-contact pachymeter, auto-refractometer and keratometer in one unit. In addition to the objective refraction, the keratometer values and the pachymetry can be determined with precision in a matter of seconds with the PARK 1®.

  • Features

    Reconditioned

    Oculus PARK 1 Auto-refractor/Keratometer/Pachymeter

    Up to Three Measurements in a Matter of Seconds

    • Auto-refractor
    • Keratometer
    • Pachymeter 
     
     

    Contact Lens Database

    The integrated contact lens database for soft contact lenses (sph, tor, multifocal) supplies a list of recommendations based on the objectively measured data. Individually adjustable parameters, such as subjective refraction, wear duration and contact lens type, allow the patient's preferences to be taken into consideration.

     

    Touchscreen

    Menu navigation on the touchscreen ensures intuitive and easy operation.

    Automatic Measurement Release

    The automatic measurement release provides reproducible measuring results in a matter of seconds:

    • Objective refraction values
    • Keratometer values
    • Pachymetry in the apex
    • Diameter of the cornea
    • Pupil diameter
    • Far PD

    RED DOT Award - Design-Prize

    The PARK 1® won the RED DOT Award for its slim, ergonomic, space-saving design.

       
    Functions

    Auto-Refractometer

    Measurement of the objective refraction data in seconds, with reproducible results. Specification of a quality factor provides information about the usability or the quality of the conducted measurement. The reliably determined data come very close to the subjective refraction.

     
     

    Keratometer

    The integrated, distance-independent keratometer guarantees measurement of the central radii with the greatest of accuracy.

     
     

    Pachymeter

    The optional, non-contact pachymetry is based on Scheimpflug images and makes precise non-contact measurement of the corneal thickness possible.

    • Measurement of the corneal thickness in the apex and the minimum corneal thickness in the entire measuring area
    • Measurement of 600 absolute height values on a horizontal
      4 mm cut through the apex
    • Presentation of the corneal thickness profile in the form of a diagram. Automatic adjustment of the scaling of the Pachymetry measurements for better presentation of the individual thicknesses
    • Pachymetry-based correction of the separately measured intraocular pressure
     
     

    Optional Database for Soft Contact Lenses
    with Fitting Recommendation

    • Fitting recommendation for soft contact lenses (based on the objective refraction, corneal diameter and central corneal radii measurements)
    • Adaptable list of contact lenses in the unit
    • The stabilization axis can be taken into account for fitting toric lenses
    • Over-refraction support
    • OxiMap® – Visualization of the oxygen transmissibility of soft contact lenses
     
     

    Automatic Measurement Release

    Thanks to the automatic measurement release, you always get reproducible measuring results. The diameters of the pupil and cornea, and the pupillary distance are determined automatically. Manual measurement is no longer necessary.

     
       
      
     
    Pachymeter (P)
    Measuring range 200 bis 1200 μm
    Number of evaluated measuring points 600
    Measuring time Approx. 1 sec.
    Light source Blue LEDs (455 nm UV-free)

    Auto-Refractometer (AR)
    Corneal vertex distance (CVD) 0; 10.5; 12; 13.75; 15; 16.5 mm
    Sphere -20 to +22 dpt (CVD = 12 mm) (choice of 0.01-; 0.12- or 0.25 dpt increments)
    Cylinder 10 dpt (CVD = 12 mm) (choice of 0.01-; 0.12- and 0.25 dpt increments)
    Axis 0° to 180° (in 1° increments)
    Smallest measurable pupil diameter 2.5 mm
    Fixation image Hot air balloon in a landscape

    Keratometer (K)
    Measuring range 9 to 99 dpt
    3 to 38 mm
    Accuracy ± 0.1 dpt
    Reproducibility ± 0.1 dpt

    Far PD 20 to 80 mm (in 1 mm increments)
    Corneal diameter measuring range 10 to 14 mm (in 0.1 mm increments)
    Pupil diameter measuring range 1 to 8 mm (in 0.1 mm increments)
    Auto alignment Automatic height alignment (y-direction)
    Auto release Automatic measurement release
    Working distance Approx. 36 mm
    Dimensions H x W x D 500 x 265 x 538 mm
    Weight 12 kg
    Power supply 100 - 240 VAC, 50 - 60 Hz
    Printer Thermal printer
    Display TFT - LCD 5.7" (Touchscreen)
    Interface USB
    Standard accessories Printer paper, power cable, dust cover, chin rest paper, USB mini cable

    Product Details

    Warranty
    6 Months
    1 Item
    Used

    Reviews (0)

    No reviews
    Product added to wishlist
    Product added to compare.

    This website, like most websites, uses Cookies to improve and optimize the user experience. Below you will find detailed information about what "Cookies" are, what type this website uses, how you can deactivate them and how to specifically block the installation of third party Cookies. View Policy